VxVM Troubleshooting – Procedure to Replace Internal FibreChannel (FC) Disks controlled by VxVM

Ramdev

I have started unixadminschool.com ( aka gurkulindia.com) in 2009 as my own personal reference blog, and later sometime i have realized that my leanings might be helpful for other unixadmins if I manage my knowledge-base in more user friendly format. And the result is today's' unixadminschool.com. You can connect me at - https://www.linkedin.com/in/unixadminschool/

Loading Facebook Comments ...

5 Responses

  1. satya says:

    HI,
    how to bring diks from veritas to OS control

  2. @Satya, below are the general steps to release disks from Veritas control.

    1.) Check the disk status.
    # vxdisk list

    2.) Remove the disk from Diskgroup.
    # vxdg -g diskgroup rmdisk disk-name

    3.) Verify the disk status.
    # vxdisk list

    4.) Unsetup the disk i.e release the disk from Veritas control to OS control.
    # vxdiskunsetup -C

  3. Ramesh says:

    Very Good Doc Youges..

  4. Yogesh Raheja says:

    @Ramesh, Thank you.

  1. October 6, 2015

    […] Backup Read – Unable to get EMC storage Lun’s visible under veritas control in Linux. Read – Troubleshooting – Procedure to Replace Internal FibreChannel (FC) Disks controlled by […]

Leave a Reply

Your email address will not be published.

[contact-form to='ramkumar.ramadevu@gmail.com' subject='New Learning Request Submitted'][contact-field label='Name' type='name' required='1'/][contact-field label='Email' type='email' required='1'/][contact-field label='Learning Request' type='textarea' required='1'/][contact-field label='Are you Looking for ' type='radio' required='1' options='Paid Training,Free Training'/][/contact-form]

What is your Learning Goal for Next Six Months ? Talk to us